Hoshizaki DCM-750BWH-OS Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Soluções para fazer cubos de gelo Hoshizaki DCM-750BWH-OS. Hoshizaki DCM-750BWH-OS User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Hoshizaki

Hoshizaki“A Superior Degreeof Reliability”www.hoshizaki.comModelsDCM-750BAHDCM-750BAH-OSDCM-750BWHDCM-750BWH-OSCubelet Icemaker / DispenserHoshizaki

Página 2 - IMPORTANT

02. DCM-750BWH(-OS)Storage BinInlet Water ValveReservoirControl BoxWater-Cooled CondenserSpout CoverEvaporator AssemblyCompressorDispensing Motor Agi

Página 3 - CONTENTS

B. Ice Making Unit1. DCM-750BAH(-OS)Cubelet CutterAllen Head Cap ScrewGear MotorO-RingMechanical SealExtruding Headand Upper BearingHex Head Bolt wi

Página 4

C. Sequence of OperationThe steps in the sequence are as outlined below. When power is supplied, the power switch is in the "ON" position,

Página 5 - A. Icemaker

3Legend:BC - bin controlComp - compressorDC - drain cycleDT - drain timerDV - drain valveFMS - self-contained fan motorFT - ll timer (low water safe

Página 6 - 2. DCM-750BAH-OS

4D. Control Board• A Hoshizaki exclusive solid-state control board is employed in DCM-750BAH, DCM-750BAH-OS, DCM-750BWH, and DCM-750BWH-OS Cubelet Ic

Página 7 - 3. DCM-750BWH

5Microprocessor (board revision level indicated by last  digits on label)"POWER" LED(lights when power is supplied to the board)"FLUS

Página 8 - 4. DCM-750BWH-OS

6Dispensing Components See "III.B. Wiring Diagrams" for details.Bin Control, Control Switch,Low Water SafetyMicroprocessor (board revision

Página 9 - A. Construction

72. FeaturesThe control board provides the following safeguards:• Provides component protection during low water supply.• Purges remaining ice in the

Página 10

83. Controls and Adjustments a) Portion ControlWhen the dispense mode switch is placed in the "PORTION" position, a variable resistor (loca

Página 11 - B. Ice Making Unit

93. 60 seconds after the "GM" LED comes on, the "COMP" LED comes on, and the compressor and fan motor start. If the "COMP&qu

Página 12 - C. Sequence of Operation

IMPORTANTOnly qualied service technicians should attempt to install, service, or maintain this icemaker. No service or maintenance should be underta

Página 13 - Shutdown & Restart

0E. Float SwitchDepending on local water conditions, scale may build up on the oat switch. Scale on the switch can cause the oats to stick. In this

Página 14 - D. Control Board

III. Technical InformationA. Water Circuit and Refrigeration Circuit1. DCM-750BAH(-OS)Inlet Water ValveDispensing Water ValveDrain ValveFloat Switch

Página 15 - Control Board

2. DCM-750BWH(-OS) Inlet Water ValveDispensing Water ValveDrain ValveFloat SwitchWater LevelTo DrainEvaporatorSpoutExpansion ValveGear MotorOverowR

Página 16

3BK BLACKBR BROWNBU BLUEDBU DARK BLUEGY GRAYLBU LIGHT BLUEO ORANGEP PINKR REDV VIOLETW WHITEY YELLOWW/BK WHITE/BLACKW/BR WHITE/BROWNW/BU WHITE/BLUEW/

Página 17

42. DCM-750BAH-OS, DCM-750BWH-OS BK BLACKBR BROWNBU BLUEDBU DARK BLUEGY GRAYLBU LIGHT BLUEO ORANGEP PINKR REDV VIOLETW WHITEY YELLOWW/BK WHITE/BLACKW

Página 18

5C. Sequence of Electrical Circuit – Ice Making1. Fill Cycle With the power switch in the "ON" position and the control switch in the "

Página 19

62. Ice Purge Cycle Upper oat switch closes, water control relay energizes, inlet water valve closes, gear motor starts, gear motor protect relay en

Página 20 - E. Float Switch

73. Freeze Cycle Compressor and fan motor start 60 seconds after gear motor starts.BK BLACK O ORANGE W/BK WHITE/BLACKBR BROWN P PINK W/BR WHITE/BROWN

Página 21 - III. Technical Information

84. 12 Hour Drain Cycle / Drain Switch hour timer initiates cycle or the control switch is moved to the "DRAIN" position. 90 seconds afte

Página 22 - 2. DCM-750BWH(-OS)

95. ShutdownThe bin control switch is activated and a 50 second shutdown sequence begins. After the bin control has been open for 90 seconds, the co

Página 23 - B. Wiring Diagrams

3IMPORTANTThis manual should be read carefully before the icemaker is serviced ormaintenance operations are performed. Only qualied service technicia

Página 24 - WIRE COLOR CODE

306. Low Water Safety Upper oat switch fails to close within 90 seconds after the lower oat switch opens, the 50 second shutdown sequence begins. T

Página 25

37. High Pressure Switch When the high pressure switch opens, the compressor stops immediately, 60 seconds later the gear motor stops. To restart, al

Página 26

3D. Sequence of Electrical Circuit – Dispensing 1. Continuous DispenseAgitating motor energizes for .6 seconds for every  seconds of accumulative d

Página 27

332. Portion DispenseAgitating motor energizes for .6 seconds for every  seconds of accumulative dispense time. A variable resistor which controls t

Página 28 - Manual Drain Cycle

34E. Performance Data1. DCM-750BAH(-OS)Note:. The data without *marks should be used for reference only.. We reserve the right to make changes in sp

Página 29

352. DCM-750BWH(-OS)Note:. The data without *marks should be used for reference only.. We reserve the right to make changes in specications and des

Página 30

36IV. Service DiagnosisA. Diagnostic ProcedureThis diagnostic procedure is a sequence check that allows you to diagnose the electrical system and comp

Página 31

376) Rell /Low Water Safety – As ice is produced, the water level in the reservoir drops. As the water level drops, the upper and lower oat switches

Página 32

38C. Diagnostic Charts1. No Ice ProductionProblem Possible Cause Remedy[]The icemaker will not start. (Fill Cycle)a) Power Supply . Off, blown fuse,

Página 33

39Problem Possible Cause Remedy[]The icemaker will not start. (Fill Cycle) (continued)m)High Pressure Switch . Bad contacts. . Check for continuity

Página 34 - E. Performance Data

4E. Performance Data ... 34. DCM-750BAH(-OS) ...

Página 35

40Problem Possible Cause Remedy[3]Ice purge cycle will not start.a) Water Control Relay . Low water safety circuit open (bad contacts ).. Replace.b

Página 36 - A. Diagnostic Procedure

4Problem Possible Cause Remedy[5] All components run, but no ice is produced. (continued)d) Evaporator . Defective. . Replace.e) Water Supply Line

Página 37 - B. Ice Production Check

43. OtherProblem Possible Cause Remedy[]Icemaker will not stop when bin is lled with ice.a)Bin Control . Actuator sticking. . Adjust or replace.

Página 38 - C. Diagnostic Charts

43Problem Possible Cause Remedy[4] Gear motor overload protector operates frequently or fuse blows frequently.a)Power Supply . Not within specicatio

Página 39

44Problem Possible Cause Remedy[]Abnormal noise. a) Gear Motor or Gear Head. Bearing worn out. . Replace.b) Auger Mechanism . Bad alignment of aug

Página 40

45Problem Possible Cause Remedy[]No water dispensed. a) OS Sensor . Dirty sensor. . Clean..Defective. . See chart 5c below.b) Dispense Mode Switc

Página 41 - 2. Low Ice Production

46V. Removal and Replacement of ComponentsIMPORTANT. Ensure all components, fasteners, and thumbscrews are securely in place after the equipment is s

Página 42 - 3. Other

47) Always install a new drier every time the sealed refrigeration system is opened. Do not replace the drier until after all other repair or replace

Página 43 - 4. Dispensing

48B. Removal and Replacement of CompressorIMPORTANTAlways install a new drier every time the sealed refrigeration system is opened. Do not replace the

Página 44 - 5. Opti Serve (OS) Sensors

49C. Removal and Replacement of Expansion ValveIMPORTANTSometimes moisture in the refrigeration circuit exceeds the drier capacity andfreezes up at th

Página 45 - 5c. Water Dispensing

5I. SpecicationsA. Icemaker1. DCM-750BAHNote: We reserve the right to make changes in specications and design without prior notice.AC SUPPLY VOLTAGE

Página 46

50Fig. 1Extruding Head and Upper BearingEvaporatorAllen Head Cap Screw with Washer Allen Head Cap ScrewHousing and Lower BearingGear MotorBarrier/Capa

Página 47

51. Upper Bearing Wear Check To ensure that the bearing inside the extruding head does not exceed the wear tolerance of .0", follow the instruc

Página 48

58) Replace spout A, spout B, and the front cover of the storage bin in their correct positions.9) Move the power switch to the "ON" positi

Página 49

533) Remove the apron panel, then remove the left side panel.4) Recover the refrigerant and store it in an approved container.5) Disconnect the drip t

Página 50

545. Removal and Replacement of Mechanical Seal and Lower Housing 5a. Mechanical Seal) Move the control switch to the "DRAIN" position and

Página 51

558) Move the power switch to the "ON" position, then replace the panels in their correct positions.9) Turn on the power supply, then mov

Página 52

56E. Removal and Replacement of Self-Contained Air-Cooled CondenserIMPORTANTAlways install a new drier every time the sealed refrigeration system is o

Página 53

57F. Removal and Replacement of Water-Cooled CondenserIMPORTANTAlways install a new drier every time the sealed refrigeration system is opened. Do not

Página 54

58G. Removal and Replacement of Water Regulating Valve - Water-Cooled Model OnlyIMPORTANTAlways install a new drier every time the sealed refrigeratio

Página 55

590) Move the power switch to the "ON" position, then replace the panels in their correct positions.) Turn on the power supply, then move

Página 56

62. DCM-750BAH-OSNote: We reserve the right to make changes in specications and design without prior notice.AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120

Página 57

60J. Removal and Replacement of Inlet or Dispensing Water Valve) Close the water supply line shut-off valve.) Open the water supply line drain valve

Página 58 - Water-Cooled Model Only

60) Open the water supply line shut-off valve.) Turn on the power supply, move the power switch to the "ON" position, then replace the f

Página 59

66) Install the new motor.7) Assemble the removed parts in the reverse order of which they were removed.8) Move the power switch to the "ON"

Página 60

63VI. Cleaning and MaintenanceIMPORTANTEnsure all components, fasteners, and thumbscrews are securely in place after any cleaning or maintenance is do

Página 61

641. Water Systema) Cleaning SolutionDilute 9.6 . oz. (0.9 l) of recommended cleaner, Hoshizaki "Scale Away" or "LIME-A-WAY" (Ec

Página 62

653) Move the control switch to the "OFF" position, then turn off the power supply.4) Close the water supply line shut-off valve.c) Saniti

Página 63 - VI. Cleaning and Maintenance

663) Remove the front cover of the storage bin.4) Remove the motor bracket thumbscrews, rst from the vertical plane and then from the horizontal plan

Página 64

67B. MaintenanceThis icemaker must be maintained individually, referring to the instruction manual and labels provided with the icemaker. The schedule

Página 65

68C. Preparing the Icemaker for Long StorageCAUTIONWhen the icemaker is not used for two or three days under normal conditions, it is sufcient to onl

Página 66

692. On water-cooled model only, remove the water from the water-cooled condenser:) Make sure the control switch and the power switch are in the &quo

Página 67 - B. Maintenance

7Note: We reserve the right to make changes in specications and design without prior notice.3. DCM-750BWHAC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120 V

Página 68

84. DCM-750BWH-OSNote: We reserve the right to make changes in specications and design without prior notice.AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120

Página 69

9II. General InformationA. Construction1. DCM-750BAH(-OS)Storage BinInlet Water ValveReservoirControl BoxAir-Cooled CondenserSpout CoverEvaporator Ass

Comentários a estes Manuais