Hoshizaki
“A Superior Degree
of Reliability”
www.hoshizaki.com
Models
KM-501MAH
KM-501MWH
KM-501MRH
Modular Crescent Cuber
Hoshizaki America, Inc.
Issued: 2-13-2006
INSTRUCTION MANUAL
Vista de página 0
1 2 3 4 5 6 ... 26 27

Resumo do Conteúdo

Página 1 - Hoshizaki

Hoshizaki“A Superior Degreeof Reliability”www.hoshizaki.comModelsKM-501MAHKM-501MWHKM-501MRHModular Crescent CuberHoshizaki America, Inc.Issued: 2-13-

Página 2 - IMPORTANT

10II. Installation and Operating InstructionsA. Checks Before InstallationIMPORTANT1. Remove shipping carton, tape(s) and packing. If packing materia

Página 3 - CONTENTS

11IcemakerBinBoltsMountingBracketsC. LocationWARNINGThis icemaker is not intended for outdoor use. Normal operating ambient temperature should be with

Página 4 - HOSHIZAKI ICE MAKER

12E. Electrical ConnectionWARNING1. Electrical connection must be made in accordance with the instructions on the "WARNING" tag, provided wi

Página 5

13F. Installation of Remote Condenser Unit1. Checks Before Installation1) Unpack and remove shipping carton, tape(s) and packing.2) Check that the ref

Página 6

143. Setup1) Secure the legs to the condenser unit with eight M8 x 16 mm hexagon bolts and M8 nuts as shown in the illustration. See Fig. 5.Note: Loca

Página 7 - B. Dimensions / Connections

154. Electrical ConnectionWARNINGThis remote condenser unit requires a ground that meets the national and local electrical code requirements. To preve

Página 8 - Unit: inches (mm.)

165. Stacking Condenser Unit1) Secure the lower condenser unit to the legs with eight bolts (not included).2) Attach the upper condenser unit on the t

Página 9 - 3. KM-501MRH

17G. Water Supply and Drain Connections See Fig. 9CAUTIONTo prevent damage to the pump assembly, do not operate the icemaker when the water supply

Página 10

18 KM-501MWH KM-501MAH KM-501MRH Fig. 9

Página 11 - D. Setup

19H. Final Checklist 1) Is the icemaker level?2) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F and the water tempe

Página 12 - E. Electrical Connection

2IMPORTANTOnly qualified service technicians should attempt to install, service or maintain this icemaker. No installation, service or maintenance shou

Página 13

20I. StartupCAUTION1. All parts are factory-adjusted. Improper adjustments may result in failure.2. If the unit is turned off, wait for at least 3 min

Página 14

21J. Preparing the Icemaker for Long StorageCAUTIONWhen shutting off the icemaker for an extended time, drain out all water from the water line and re

Página 15

223. Follow the instructions below to drain the potable water tank.1) Turn off the power supply.2) Move the control switch on the control box to the &

Página 16

23III. Cleaning and Maintenance InstructionsIMPORTANTEnsure all components, fasteners and thumbscrews are securely in place after any maintenance or c

Página 17 - See Fig. 9

241. Cleaning Procedure1) Dilute approximately 16 fl. oz. of recommended cleaner Hoshizaki "Scale Away" or "LIME-A-WAY," (Economic

Página 18 - KM-501MRH

252. Sanitizing Procedure - Following Cleaning Procedure1) Dilute a 5.25% sodium hypochlorite solution with water (Add 1.5 fl. oz. of sanitizer to 3 ga

Página 19 - H. Final Checklist

26B. MaintenanceIMPORTANTThis icemaker must be maintained individually, referring to the instruction manual and labels provided with the icemaker.1. S

Página 20 - I. Startup

27HOSHIZAKI AMERICA, INC.618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 91A1MN10A

Página 21

3• Please review this manual. It should be read carefully before the icemaker is installed and operated. Only qualified service technicians should inst

Página 22

4I. SpecificationsA. Nameplate Rating1. KM-501MAH (air-cooled)See the nameplate for electrical and refrigeration specifications. This nameplate is locat

Página 23 - A. Cleaning Instructions

52. KM-501MWH (water-cooled)See the nameplate for electrical and refrigeration specifications. This nameplate is located on the upper right hand side o

Página 24

63. KM-501MRH (remote air-cooled)See the nameplate for electrical and refrigeration specifications. This nameplate is located on the upper right hand s

Página 25

7B. Dimensions / Connections1. KM-501MAHUnit: inches (mm.)

Página 26 - B. Maintenance

82. KM-501MWHUnit: inches (mm.)

Página 27 - HOSHIZAKI AMERICA, INC

93. KM-501MRHUnit: inches (mm.)